Step 1
![](https://www.brightwell.co.uk/wp-content/uploads/2023/09/Wiring-the-Trigger-Signals-Step-1-6.gif)
The Trigger Signals are located inside the unit on the right side board. If you are looking to wire Common Input trigger signals with a Common Neutral use the 2 way connector and 9 way A rail shown here.
Step 2
Wire the Common Neutral into the two way and connect your Trigger Connections into slots 1-8 in the 9 way connector as required.
![](https://www.brightwell.co.uk/wp-content/uploads/2024/01/Wring-the-Trigger-Signals-Step-2.gif)
Step 3
![](https://www.brightwell.co.uk/wp-content/uploads/2023/10/Wiring-the-Trigger-Signals-Step-3-1.gif)
Place the Common Neutral connector back into the two way slot shown below.
Step 4
Connect any common trigger signals into the A rail as shown.
![](https://www.brightwell.co.uk/wp-content/uploads/2023/10/Wiring-the-Trigger-Signals-Step-4-1.gif)
Step 5
![](https://www.brightwell.co.uk/wp-content/uploads/2023/10/Wiring-the-Trigger-Signals-Isolated-Step-5.gif)
Confirm that the Dip switches are in the BOTTOM position for the Common Neutral.
Step 6
The last step is to define if the trigger signals are HIGH or LOW. High are for voltages between 110-240 volts. Low is for voltages between 12-24 volts.